Infrared analyser INSTALAB 600


Quick Overview

Excellent structure and quality during the production of infrared analyzers of series Instalab 600 guarantees obtaining the most reliable and accurate results. The rotating sample holder actually eliminates the problems associated with sample inhomogeneity. The research shows that this principle allows obtaining three times more accurate results than in the analyzers which use other technologies. Reliability has significantly increased in relation to using the standard sample which is built-in the optical system.

Purpose and area of application:

No other company in the world has such big experience in developing and production of NIR analyzers as DICKEY-john Corporation. This experience is materialized in unique NIR spectrum technology of devices, series 600. This is the best analyzer in terms of reliability, accuracy and cost ratio.

Excellent structure and quality during the production of infrared analyzers of series Instalab 600 guarantees obtaining the most reliable and accurate results. The rotating sample holder actually eliminates the problems associated with sample inhomogeneity. The research shows that this principle allows obtaining three times more accurate results than in the analyzers which use other technologies. Reliability has significantly increased in relation to using the standard sample which is built-in the optical system.
   The unparalleled feature of DICKEY-john device is Optigain® system which allows the user to measure samples with low coefficient of reflection. There is one more specific feature - it is the detector with thermo-electrical cooling, which is provided with a high level of sensitivity and a big dynamic range. Analyzers of Instalab 600 Series are designed for failure-free operation actually for any type of external conditions - from laboratories to production lines.

Express analysis of oil-bearing crops (maize sunflower seeds, rape, cotton). Measurable aspects:

  • moisture;
  • fat;
  • glucosinolates (rape, whole grain);
  • erucidic acid (rape, whole grain);
  • protein (raw protein);
  • starch;
  • cellular tissue .

Express analysis of grain products (wheat, barley, rice, ...) and their products. Measurable aspects:

  • moisture;
  • protein;
  • gluten;
  • cellular tissue;
  • starch.

Analysis of meat and dairy products (meat, cheese, dairy products, mayonnaise).
   Features:

  • depending on the analyzer configuration, simultaneous measurement of 2-4 parameters is possible;
  • in some cases preliminary grinding of the sample is required.
Модель INSTALAB 600
Number of filters, units 4 - 10
Number of graduation marks up to 52
Computer output / input RS-232-C
Printer option
Accuracy in accordance with GOST
for a certain type of product
Sample cell rotating
Filament lamp halogen with tungsten filament
Certification for every separate device
Record of graduation marks volatile memory, EPROM type
Measurement time, s 10
Detector with thermoelectric cooling based on lead sulfide
Method of signal measurement by comparing the reflected spectral radiation from the sample
and from the built-in reference ceramic disk
Automatic signal control switching on ‘Optigain’ feature for dark samples
Diagnostics automatic testing after each measurement
Power supply 102-132 V, 57-63 Hz or 187-242 V, 47-53 Hz
Weight, kg 29,5
Overall dimensions, cm
height
width
depth

34,6
56,5
41,5
Меню